Linshang LS162 tint meter with a glass sample in the slot, reading 36.9 VLT, 99.9 UVR and 85.5 IRR

Linshang LS162 Window Tint Meter: VLT, UV & IR Rejection

Sale price  $139.69 Regular price  $199.99 Save 30%
Skip to product information
Linshang LS162 tint meter with a glass sample in the slot, reading 36.9 VLT, 99.9 UVR and 85.5 IRR

Linshang LS162 Window Tint Meter: VLT, UV & IR Rejection

Sale price  $139.69 Regular price  $199.99 Save 30%
Shipping calculated at checkout.
  • Secure checkout Encrypted payment through Shopify
  • Ships fast Orders processed in 1–3 business days
  • Free local pickup Choose pickup at checkout
  • Real people (925) 752-8024 · Return policy

The Linshang LS162 is a handheld tint meter that reads visible light transmission (VLT), UV rejection (UVR) and IR rejection (IRR) at the same time. Slide glass or a film sample into the slot and read all three. Built for tint shops that check VLT, demo films to customers and compare film lines.

Key features

  • Reads VLT, UVR and IRR together on one LCD
  • UV peak 365 nm, IR peak 940 nm
  • 0.1% resolution; accuracy better than ±2% on clear, uniform material
  • ON/Hold button freezes a reading for customer demos
  • Slot takes samples up to 8 mm thick
  • Runs on 4 AAA batteries

Best for

  • Checking VLT on roll-down side windows
  • Customer demos on film samples and display boards
  • Comparing film lines in the shop
  • Flat glass and film samples

Specs

Model Linshang LS162 Transmission Meter
Readings VLT, UVR, IRR (shown together)
UV peak wavelength 365 nm
IR peak wavelength 940 nm
Visible light range 380-760 nm (CIE photopic)
Resolution 0.1%
Accuracy Better than ±2% (colorless, uniform transparent material)
Max sample thickness Under 0.31" (8 mm)
Display Segment LCD
Dimensions 4.7" x 3.0" x 1.0" (120 x 75 x 25 mm)
Power 4 x AAA batteries

How to use

  1. Press ON/Hold to power up.
  2. With the slot empty, check it reads VLT 100, UVR 0.0 and IRR 0.0.
  3. Slide the glass edge or film sample fully into the slot and hold it still.
  4. Read VLT, UVR and IRR. Press ON/Hold to freeze the reading.
  5. Wipe off slip solution and keep the slot clean.

FAQ

Can it read a windshield or back glass?

Only if the glass edge fits the slot (under 8 mm thick). It works on roll-down side windows, loose glass and film samples.

What's the difference between the LS162 and the LS162A?

Both read VLT, UV and IR. The LS162 measures IR rejection at 940 nm. The LS162A uses 1400 nm. This listing is the LS162.

Why does the screen show 100 / 0.0 / 0.0 with nothing in it?

That's the empty-slot reading: all visible light passes and nothing is rejected. Use it as a quick check before you measure.

You may also like